Thermal Resistance Converter

Convert thermal resistance between K/W, °C/W, RSI, and US R-value. Essential for insulation specification, building codes, and electronic heat sink design.

square_foot Length
Kilometers keyboard_arrow_down
km
Miles keyboard_arrow_down
mi
info Formula: multiply the length value by 0.621

Thermal Resistance in Building Insulation and Electronics

Thermal resistance measures how strongly a material or assembly opposes the flow of heat. The higher the thermal resistance, the better its insulating ability. The SI unit is kelvin per watt (K/W) or, for area-specific thermal resistance, square metre kelvin per watt (m²·K/W — the RSI value). In North America, the familiar US R-value (hr·ft²·°F/BTU) is used for building insulation rating.

Thermal resistance is used in two distinct contexts: in building science, it rates the insulation value of walls, roofs, and windows; in electronics, it characterises the heat dissipation path from a component's junction to the ambient environment. Both applications use the same fundamental equation: temperature difference = heat flow × thermal resistance (ΔT = Q × R), but operate on very different scales.

US R-Values and Building Codes

The US R-value system rates insulation by how many BTU of heat pass through one square foot of material per hour per degree Fahrenheit of temperature difference across it. A higher R-value means better insulation. The unit is hr·ft²·°F/BTU, usually written simply as R-13, R-19, R-30, etc. The US Department of Energy (DOE) recommends R-49 to R-60 for attic insulation in cold climate zones (zones 5–8), and R-13 to R-21 for exterior walls in most of the country.

IRC (International Residential Code) and IECC (International Energy Conservation Code) prescribe minimum R-values for each building component in each climate zone. A new home in Chicago (zone 5) must achieve at least R-49 in the attic, R-20 in above-grade walls, and R-10 under the foundation slab. These minimums are set to achieve acceptable heating and cooling loads for energy efficiency.

UK RSI Values and Part L

The UK uses the RSI (metric R-value) system, where the unit is m²·K/W. UK building regulations Part L (Conservation of Fuel and Power) specify maximum U-values (W/(m²·K)) for new construction elements. U-value is the inverse of total RSI: U = 1/RSI. A typical UK external wall with cavity fill insulation might have U = 0.28 W/(m²·K), corresponding to RSI = 3.57 m²·K/W or US R-value ≈ 20.3.

The conversion between US R-value and RSI is: RSI = US R × 0.1761. Conversely, US R = RSI × 5.678. An architect specifying double-glazed windows with US R-3 glazing translates that to RSI 0.53 m²·K/W for UK regulatory compliance submissions. The RSI value is also used in ASHRAE and ISO thermal standards.

Electronic Heat Sinks: K/W and °C/W

In electronics, thermal resistance is expressed in kelvin per watt (K/W) or equivalently °C/W (numerically identical since K and °C intervals are equal). A microprocessor has a junction-to-case thermal resistance (θ_jc) specified in °C/W by the manufacturer. If θ_jc = 0.5 °C/W and the chip dissipates 100 W, the junction temperature will be 50 °C above the package case temperature.

Heat sink selection requires adding thermal resistances in series: θ_j-ambient = θ_jc + θ_c-s (case-to-sink contact resistance) + θ_s-a (heat sink-to-ambient). If θ_s-a = 0.8 °C/W and ambient is 35 °C, the junction reaches 35 + (0.5 + 0.1 + 0.8) × 100 = 175 °C — at or above the maximum junction temperature for many processors. US manufacturers (Intel, AMD) and UK chipmakers (ARM, Imagination) publish θ_jc in °C/W; converting to K/W is trivial (the values are numerically equal).

Practical Conversion Reference

Engineers regularly encounter both US R-values and RSI in the same project. An international retrofit project might have US insulation products rated in R-values and a UK-origin mechanical specification using RSI. The relationship is simple: 1 US R-value = 0.1761 RSI. For component-level thermal resistance: 1 K/W = 1 °C/W (numerically equal). For area-specific: 1 RSI (m²·K/W) = 5.678 US R-value. These conversions must be accurate to avoid significant errors in energy modelling and compliance calculations.

Core Conversion Formulas

The underlying mathematics used by our converter engine.

Conversion Exact Mathematical Formula
US R-value → RSI (m²·K/W) RSI = R × 0.17611
RSI → US R-value R = RSI × 5.6783
K/W → °C/W °C/W = K/W (numerically equal)
RSI → U-value (W/(m²·K)) U = 1 ÷ RSI
°F·hr/BTU → K/W K/W = °F·hr/BTU × 0.52750

Frequently Asked Questions

What is the difference between US R-value and RSI?

Both measure area-specific thermal resistance. US R-value uses Imperial units (hr·ft²·°F/BTU); RSI uses SI units (m²·K/W). The conversion is: RSI = US R × 0.1761. An R-20 wall equals RSI 3.52 m²·K/W. Higher values mean better insulation in both systems.

What does R-value mean on insulation packaging?

The US R-value printed on insulation products (R-13, R-19, R-30, etc.) indicates how strongly the insulation resists heat flow. R-13 is standard fiberglass batt insulation for 2×4 walls; R-21 for 2×6 walls; R-30 or higher for attics. A higher R-value means less heat loss per degree of temperature difference, resulting in lower heating and cooling bills.

Why does UK use U-value instead of R-value?

The UK and EU building regulations specify maximum U-values (W/(m²·K)), which measure heat conductance rather than resistance. U-value = 1/RSI, so a lower U-value means better insulation. A UK building regulation limit of U = 0.18 W/(m²·K) corresponds to RSI = 5.56 m²·K/W or US R-31.5.

What is thermal resistance in a computer heat sink?

Heat sink thermal resistance (θ in K/W or °C/W) describes how much the heat sink temperature rises above ambient per watt of heat dissipated. A heat sink with θ = 0.5 °C/W dissipating 50 W will be 25 °C above ambient. Lower thermal resistance (better heat sinks) keep components cooler.

How do I calculate total wall R-value?

Add the R-values of each layer in series: sheathing + insulation + drywall + air films. For example, R-19 batt + R-2 sheathing + R-1 drywall + R-1 air films = R-23 total. In SI (RSI), add the RSI values of each layer: RSI-total = RSI-3.35 + RSI-0.35 + RSI-0.18 + RSI-0.18 = RSI-4.06.

thermostat

Real-World Benchmarks

  • US attic insulation (code min.)

    Climate zone 5–8

    R-49–R-60

    RSI 8.6–10.6

  • UK Part L external wall

    New build 2023

    U ≤ 0.18 W/(m²·K)

    RSI ≥ 5.56

  • Intel Core i9 processor θ_jc

    Junction to case

    ~0.5 °C/W

    ~0.5 K/W

  • Double-glazed window (US)

    Typical spec

    R-3

    RSI 0.53

  • Aerogel blanket insulation

    High-performance

    R-10 per inch

    RSI 0.70/cm