Thermal Resistance Converter
Convert thermal resistance between K/W, °C/W, RSI, and US R-value. Essential for insulation specification, building codes, and electronic heat sink design.
Thermal Resistance in Building Insulation and Electronics
Thermal resistance measures how strongly a material or assembly opposes the flow of heat. The higher the thermal resistance, the better its insulating ability. The SI unit is kelvin per watt (K/W) or, for area-specific thermal resistance, square metre kelvin per watt (m²·K/W — the RSI value). In North America, the familiar US R-value (hr·ft²·°F/BTU) is used for building insulation rating.
Thermal resistance is used in two distinct contexts: in building science, it rates the insulation value of walls, roofs, and windows; in electronics, it characterises the heat dissipation path from a component's junction to the ambient environment. Both applications use the same fundamental equation: temperature difference = heat flow × thermal resistance (ΔT = Q × R), but operate on very different scales.
US R-Values and Building Codes
The US R-value system rates insulation by how many BTU of heat pass through one square foot of material per hour per degree Fahrenheit of temperature difference across it. A higher R-value means better insulation. The unit is hr·ft²·°F/BTU, usually written simply as R-13, R-19, R-30, etc. The US Department of Energy (DOE) recommends R-49 to R-60 for attic insulation in cold climate zones (zones 5–8), and R-13 to R-21 for exterior walls in most of the country.
IRC (International Residential Code) and IECC (International Energy Conservation Code) prescribe minimum R-values for each building component in each climate zone. A new home in Chicago (zone 5) must achieve at least R-49 in the attic, R-20 in above-grade walls, and R-10 under the foundation slab. These minimums are set to achieve acceptable heating and cooling loads for energy efficiency.
UK RSI Values and Part L
The UK uses the RSI (metric R-value) system, where the unit is m²·K/W. UK building regulations Part L (Conservation of Fuel and Power) specify maximum U-values (W/(m²·K)) for new construction elements. U-value is the inverse of total RSI: U = 1/RSI. A typical UK external wall with cavity fill insulation might have U = 0.28 W/(m²·K), corresponding to RSI = 3.57 m²·K/W or US R-value ≈ 20.3.
The conversion between US R-value and RSI is: RSI = US R × 0.1761. Conversely, US R = RSI × 5.678. An architect specifying double-glazed windows with US R-3 glazing translates that to RSI 0.53 m²·K/W for UK regulatory compliance submissions. The RSI value is also used in ASHRAE and ISO thermal standards.
Electronic Heat Sinks: K/W and °C/W
In electronics, thermal resistance is expressed in kelvin per watt (K/W) or equivalently °C/W (numerically identical since K and °C intervals are equal). A microprocessor has a junction-to-case thermal resistance (θ_jc) specified in °C/W by the manufacturer. If θ_jc = 0.5 °C/W and the chip dissipates 100 W, the junction temperature will be 50 °C above the package case temperature.
Heat sink selection requires adding thermal resistances in series: θ_j-ambient = θ_jc + θ_c-s (case-to-sink contact resistance) + θ_s-a (heat sink-to-ambient). If θ_s-a = 0.8 °C/W and ambient is 35 °C, the junction reaches 35 + (0.5 + 0.1 + 0.8) × 100 = 175 °C — at or above the maximum junction temperature for many processors. US manufacturers (Intel, AMD) and UK chipmakers (ARM, Imagination) publish θ_jc in °C/W; converting to K/W is trivial (the values are numerically equal).
Practical Conversion Reference
Engineers regularly encounter both US R-values and RSI in the same project. An international retrofit project might have US insulation products rated in R-values and a UK-origin mechanical specification using RSI. The relationship is simple: 1 US R-value = 0.1761 RSI. For component-level thermal resistance: 1 K/W = 1 °C/W (numerically equal). For area-specific: 1 RSI (m²·K/W) = 5.678 US R-value. These conversions must be accurate to avoid significant errors in energy modelling and compliance calculations.
Core Conversion Formulas
The underlying mathematics used by our converter engine.
| Conversion | Exact Mathematical Formula |
|---|---|
| US R-value → RSI (m²·K/W) | RSI = R × 0.17611 |
| RSI → US R-value | R = RSI × 5.6783 |
| K/W → °C/W | °C/W = K/W (numerically equal) |
| RSI → U-value (W/(m²·K)) | U = 1 ÷ RSI |
| °F·hr/BTU → K/W | K/W = °F·hr/BTU × 0.52750 |
Frequently Asked Questions
What is the difference between US R-value and RSI?
Both measure area-specific thermal resistance. US R-value uses Imperial units (hr·ft²·°F/BTU); RSI uses SI units (m²·K/W). The conversion is: RSI = US R × 0.1761. An R-20 wall equals RSI 3.52 m²·K/W. Higher values mean better insulation in both systems.
What does R-value mean on insulation packaging?
The US R-value printed on insulation products (R-13, R-19, R-30, etc.) indicates how strongly the insulation resists heat flow. R-13 is standard fiberglass batt insulation for 2×4 walls; R-21 for 2×6 walls; R-30 or higher for attics. A higher R-value means less heat loss per degree of temperature difference, resulting in lower heating and cooling bills.
Why does UK use U-value instead of R-value?
The UK and EU building regulations specify maximum U-values (W/(m²·K)), which measure heat conductance rather than resistance. U-value = 1/RSI, so a lower U-value means better insulation. A UK building regulation limit of U = 0.18 W/(m²·K) corresponds to RSI = 5.56 m²·K/W or US R-31.5.
What is thermal resistance in a computer heat sink?
Heat sink thermal resistance (θ in K/W or °C/W) describes how much the heat sink temperature rises above ambient per watt of heat dissipated. A heat sink with θ = 0.5 °C/W dissipating 50 W will be 25 °C above ambient. Lower thermal resistance (better heat sinks) keep components cooler.
How do I calculate total wall R-value?
Add the R-values of each layer in series: sheathing + insulation + drywall + air films. For example, R-19 batt + R-2 sheathing + R-1 drywall + R-1 air films = R-23 total. In SI (RSI), add the RSI values of each layer: RSI-total = RSI-3.35 + RSI-0.35 + RSI-0.18 + RSI-0.18 = RSI-4.06.
Real-World Benchmarks
-
US attic insulation (code min.)
Climate zone 5–8
R-49–R-60
RSI 8.6–10.6
-
UK Part L external wall
New build 2023
U ≤ 0.18 W/(m²·K)
RSI ≥ 5.56
-
Intel Core i9 processor θ_jc
Junction to case
~0.5 °C/W
~0.5 K/W
-
Double-glazed window (US)
Typical spec
R-3
RSI 0.53
-
Aerogel blanket insulation
High-performance
R-10 per inch
RSI 0.70/cm